Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.205
Filtrar
1.
Vet Anaesth Analg ; 51(1): 26-34, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37839991

RESUMO

OBJECTIVE: To investigate the effect of isoflurane anesthesia on thermoregulation and peripheral heat loss in dorsally recumbent horses. STUDY DESIGN: Prospective, clinical study. ANIMALS: Seven adult horses (2.6 ± 1.5 years old, 455 ± 70.2 kg). METHODS: Horses underwent elective surgical procedures in dorsal recumbency under general anesthesia (GA) maintained with isoflurane in oxygen. Rectal (TR), intranasal (TN) and fetlock surface temperatures (TF) were measured every 10 minutes for the first 80 minutes following induction of GA. Room temperature (TRO) was monitored during the study. Statistical analysis to determine differences between temperature measurement sites and techniques (TR, TN and TF), and differences over time were completed using a mixed-effects model with Tukey's multiple comparison or Dunnett's multiple comparison testing where appropriate. Significance was set at p < 0.05. RESULTS: Following induction of anesthesia, TF was significantly increased compared with baseline (0 minutes) from 40 to 80 minutes (p < 0.01). No significant differences were detected in TR and TN at any time point compared with baseline (p > 0.05). TF was significantly lower than TN (p < 0.02) at all time points and TR from times 0 to 70 minutes (p < 0.04). There were no significant differences between TR and TN at any time (p > 0.05). CONCLUSIONS: In horses undergoing isoflurane GA, TF increased, indicating peripheral heat loss likely because of vasodilation, whereas TR showed a clinically relevant decrease over time. These findings are suggestive of body heat redistribution during GA in horses in dorsal recumbency. Thermographic imaging of the peripheral limbs in combination with TR and TN monitoring allowed for recognition of peripheral heat redistribution in anesthetized horses. CLINICAL RELEVANCE: Anesthetized horses experience peripheral heat loss through their extremities as a result of vasodilation. Mitigating peripheral heat loss may improve thermoregulation and reduce hypothermic complications in anesthetized horses.


Assuntos
Anestesia Geral , Cavalos , Isoflurano , Termometria , Animais , Anestesia Geral/veterinária , Anestesia Geral/métodos , Temperatura Corporal , Cavalos/cirurgia , Isoflurano/farmacologia , Estudos Prospectivos , Termometria/métodos , Termometria/veterinária
2.
Vet Surg ; 53(2): 357-366, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37463876

RESUMO

OBJECTIVE: To report the use and feasibility of a self-locking resorbable loop device for cryptorchidectomy. STUDY DESIGN: Clinical prospective study. POPULATION: Twenty horses. METHODS: Horses suspected to have an abdominal testicle/s after admission work-up were enrolled. Horses were anesthetized in dorsal recumbency and a standard laparoscopic technique was performed. The looped device was inserted into the abdomen, glided around the testis/cord and tightened. Then, the spermatic cord was transected prior testis removal. Surgical procedure details and remarks, perioperative complications and total surgical time were recorded. Short- (>3 weeks) and long-term (>6 months) follow-ups were obtained by telephone questionnaire. RESULTS: Median total surgical time was 67 min (range: 43-189 min) and significantly shortened after the first four horses. The loop device was easily glided around 13/20 abdominal testes and required more time and technical skills around larger testes (≥3 years). Excellent intraoperative hemostasis was achieved in 17 horses. Three horses demonstrated mild intraoperative bleeding that required retightening, device replacement or adding a second device, respectively. Three horses developed mild postoperative hemoabdomen identified ultrasonographically and were successfully managed medically. Follow-up revealed no significant complications related to the procedure. One horse was euthanized for colic 4 months after surgery and one died of hemolytic shock 17 months postoperatively. CONCLUSION: This device represents another method to perform equine cryptorchidectomy that requires minimal training and laparoscopic expertise but demands knowledge of the device and application to prevent complications. CLINICAL SIGNIFICANCE: Laparoscopic cryptorchidectomy using this device is an alternative technique for horses <3 years.


Assuntos
Criptorquidismo , Doenças dos Cavalos , Laparoscopia , Masculino , Cavalos/cirurgia , Animais , Criptorquidismo/cirurgia , Criptorquidismo/veterinária , Estudos Prospectivos , Doenças dos Cavalos/cirurgia , Orquiectomia/veterinária , Orquiectomia/métodos , Laparoscopia/veterinária , Laparoscopia/métodos
3.
Vet Surg ; 53(1): 38-44, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37483085

RESUMO

OBJECTIVE: To determine if targeted blocking of frontal and infratrochlear nerves provided anesthesia for the approach to a frontonasal sinusotomy. STUDY DESIGN: Two part study: Part 1 randomized crossover design; Part 2 proof of concept. ANIMALS: N = 12; six each in Parts 1 and 2. METHODS: Part 1: Each horse had either frontal and infratrochlear nerve blocks or a line block performed with 2% mepivacaine hydrochloride. Mechanical nociceptive thresholds (MNT) were obtained at five sites along a proposed frontonasal sinusotomy prior to injection, and at 10, 60, and 120 min after blocking. After a 4 day washout period, the opposite procedure was performed. Order of procedure and side of face were randomized. MNTs were analyzed using mixed-model ANOVA with p < .05. Part 2: Frontal and infratrochlear nerve blocks were performed followed by creation of a skin/periosteal incision, which was closed at 2 h. Ability to create and suture the incision, and the size of the incision were recorded. RESULTS: For part 1, both line and targeted blocks resulted in at least two times an increase in median MNT values at each of the five sites, as compared to baseline MNT values (p < .0025). In Part 2, incisions could be completed in five of six horses, with median incision size of 6.5 × 5 cm. CONCLUSION: Following frontal and infratrochlear nerve blocks, MNTs were increased along a proposed frontonasal sinusotomy, and skin incisions could be created in the majority of horses. CLINICAL SIGNIFICANCE: Frontal and infratrochlear nerve blocks provide an alternative technique to create a frontonasal sinusotomy.


Assuntos
Anestésicos Locais , Bloqueio Nervoso , Cavalos/cirurgia , Animais , Mepivacaína , Bloqueio Nervoso/veterinária , Bloqueio Nervoso/métodos
4.
Vet Surg ; 53(1): 20-28, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37650350

RESUMO

OBJECTIVE: To describe a 3-wire method with endoscopic guidance for extensive nasal septum resection. STUDY DESIGN: Retrospective study. SAMPLE POPULATION: Thirteen horses with nasal septum diseases. METHODS: In anesthetized horses in left lateral recumbency, endoscopic guidance was used to place obstetrical wires for the ventral and caudal incisions in the nasal septum and a trephine opening was used to place the dorsal wire. The rostral aspect of the septum was incised with a scalpel, followed by incisions with the preplaced wires, and the nasal passages were packed with gauze. Horses were recovered with a temporary tracheotomy. RESULTS: Conversion to intraoral placement of wires was required in two horses, one to correct entangled wires and the other because hemorrhage obscured the endoscopic view. Exercise tolerance was improved postoperatively, abnormal respiratory noise was decreased or eliminated by surgery in all horses, and all owners were satisfied. One Thoroughbred racehorse performed with modest success. CONCLUSIONS: Modification of the 3-wire method was effective and safe for extensive nasal septum removal. Technical complications of the procedure include entangling of wires and intraoperative hemorrhage. CLINICAL SIGNIFICANCE: Endoscopic guidance can be used to place obstetrical wires for nasal septum resection in small horses and precludes use of a large tracheotomy for anesthetic delivery. Reasons for athletic failures were difficult to establish retrospectively, although assessment of postoperative noise at speed might be more relevant to recovery of athletic potential than assessment at slower gaits.


Assuntos
Doenças dos Cavalos , Septo Nasal , Cavalos/cirurgia , Animais , Estudos Retrospectivos , Septo Nasal/cirurgia , Cavidade Nasal/cirurgia , Endoscópios , Hemorragia/veterinária , Doenças dos Cavalos/cirurgia
5.
Vet Surg ; 53(1): 194-203, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37752808

RESUMO

OBJECTIVES: To determine the influence of a stainless-steel cable (SSC) tension band fixation as an adjunct to a locking compression plate (LCP) for arthrodesis of the equine metacarpophalangeal (MCP) joint. STUDY DESIGN: Experimental. An ex vivo biomechanical paired equine cadaver limb study. SAMPLE POPULATION: Five MCP joint pairs were collected from adult Thoroughbred horses, euthanized for reasons unrelated to orthopedic disease. METHODS: Each pair of MCP joints were randomly implanted with either a dorsally placed 5.5 mm LCP and a palmarly placed 2.0 mm SSC or a dorsally placed 5.5 mm LCP alone. Each construct was tested in cyclic loading followed by single cycle to failure in axial compression. Displacement at a target load of 1 kN over 3600 cycles at 1 Hz was recorded prior to single cycle to failure testing. RESULTS: In cyclic testing, displacement was not significantly different between the first and last 5% of testing cycles regardless of construct. Maximum displacement of each construct during cyclic testing was <1.1 mm. In single cycle testing, the observed yield point did not reveal any difference between LCP and LCP-SSC (p = .440). The maximum load at failure was significantly higher in LCP-SSC compared to constructs with the LCP alone (p = .046). CONCLUSION: The addition of the SSC to the LCP did not statistically affect construct displacement during cyclic loading or construct yield load during subsequent single cycle to failure. CLINICAL SIGNIFICANCE: This study provided much needed information regarding the necessity of a tension band SSC application in the arthrodesis of the MCP/MTP joint in horses.


Assuntos
Artrodese , Doenças dos Cavalos , Cavalos/cirurgia , Animais , Fenômenos Biomecânicos , Artrodese/veterinária , Placas Ósseas/veterinária , Articulação Metacarpofalângica/cirurgia , Cadáver , Fixação Interna de Fraturas/veterinária , Doenças dos Cavalos/cirurgia
6.
Vet Surg ; 53(1): 155-166, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37770751

RESUMO

OBJECTIVE: The aim of this study was to assess screw placement in simulated dorsomedial-plantarolateral central tarsal bone (CTB) fractures using two imaging guidance techniques - computed tomography (CT) with fluoroscopy compared to digital radiography alone (DR). STUDY DESIGN: Experimental study. SAMPLE POPULATION: Equine cadaver hindlimbs (n = 10 pairs). METHODS: One tarsus per pair was randomly assigned to have a 4.5 mm cortical screw placed across the CTB using CT and fluoroscopy (CT/F group) or digital radiography alone (DR group). Postoperative CT was performed on all limbs. Variables related to marker placement, procedure time, and screw positioning were recorded and compared using a paired t-test for dependent means (p < .05). RESULTS: Time for marker placement was longer for the CT/F group (p = .001), with no difference in total procedure time (p = .12). CT/F was not superior to radiography alone (p > .05) for parameters related to screw positioning. Based on the 95% CI, there was greater range in relative screw length using radiography (76.5%-91.2%) versus CT/F (78.4%-84.0%). CONCLUSION: Internal fixation of CTB fractures can be successfully performed using either technique for imaging guidance. CT and fluoroscopy did not result in faster or more accurate screw placement compared to radiographs alone, except in determining screw length. CLINICAL SIGNIFICANCE: Mild adjustments in fluoroscopic or radiographic angle appeared to be a point of variability in the perception of screw placement. While CT is recommended for improved understanding of fracture configuration and surgical planning, radiographic guidance may be a suitable alternative for internal fixation of dorsomedial-plantarolateral fractures.


Assuntos
Fraturas Ósseas , Doenças dos Cavalos , Ossos do Tarso , Cavalos/cirurgia , Animais , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Fraturas Ósseas/veterinária , Fixação Interna de Fraturas/veterinária , Fixação Interna de Fraturas/métodos , Fluoroscopia/veterinária , Tomografia Computadorizada por Raios X/veterinária , Tomografia Computadorizada por Raios X/métodos , Ossos do Tarso/diagnóstico por imagem , Ossos do Tarso/cirurgia
7.
Am J Vet Res ; 85(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38109844

RESUMO

OBJECTIVE: To describe the feasibility of a novel thread-transecting technique for the tenotomy of the equine deep digital flexor tendon (DDFT). ANIMALS: 39 equine distal limb specimens. METHODS: Under ultrasonographic guidance, a surgical thread was percutaneously placed around the DDFT through 2 needle punctures (lateral and medial) using a Tuohy needle in equine limbs (22 forelimbs, 17 hindlimbs). The DDFT was transected by a back-and-forth motion of the thread until the loop emerged from the entry puncture site. Each specimen was dissected and assessed for completeness of transection and iatrogenic damage under direct visualization. Descriptive statistics were reported. RESULTS: Complete DDFT transection was achieved in all 39 limbs, taking an average of 8.6 minutes per procedure. Iatrogenic damage to surrounding structures occurred in 17 (44%) limbs, with 6 (15%) limbs having more than 1 structure damaged. Damage to the communicating branch of the palmar or plantar nerves was the most commonly seen. CLINICAL RELEVANCE: DDFT tenotomy in equine limb specimens was effectively performed using a novel thread-transecting technique. The procedure is quick, and no suturing is needed, but damage to surrounding structures is possible. Further assessment of the procedure and clinical significance of its potential iatrogenic damage in clinical cases is needed.


Assuntos
Doenças do Pé , Doenças dos Cavalos , Cavalos/cirurgia , Animais , Tenotomia/veterinária , Tendões/cirurgia , , Doenças do Pé/veterinária , Doença Iatrogênica/veterinária , Membro Anterior/cirurgia , Doenças dos Cavalos/cirurgia
8.
Acta Vet Scand ; 65(1): 48, 2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-37986118

RESUMO

BACKGROUND: A 3D printed self-locking device made of polydioxanone (PDO) was developed to facilitate a standardized ligation technique. The subcutaneous tissue reaction to the device was evaluated after implantation in ten horses of mixed age, sex and breed and compared to loops of poly(lactic-co-glycolic acid) (PLGA). In two of the horses, the implants were removed before closing the skin. The appearance of the implants and surrounding tissue was followed over time using ultrasonography. Implants were removed after 10 and 27 (± 1) days for histologic examination. RESULTS: On macroscopic inspection at day 10, the PDO-device was fragmented and the surrounding tissue was oedematous. On ultrasonographic examination, the device was seen as a hyperechoic structure with strong acoustic shadowing that could be detected 4 months post-implantation, but not at 7 months. Histology revealed a transient granulomatous inflammation, i.e., a foreign body reaction, which surrounded both PDO and PLGA implants. The type and intensity of the inflammation varied between individuals and tissue category. CONCLUSIONS: The 3D printed PDO-device caused a transient inflammatory reaction in the subcutaneous tissue and complete resorption occurred between 4 and 7 months. Considering the intended use as a ligation device the early fragmentation warrants further adjustments of both material and the 3D printing process before the device can be used in a clinical setting.


Assuntos
Doenças dos Cavalos , Polidioxanona , Animais , Cavalos/cirurgia , Inflamação/veterinária , Ligadura/métodos , Ligadura/veterinária , Impressão Tridimensional , Tela Subcutânea/cirurgia , Masculino , Feminino
9.
Schweiz Arch Tierheilkd ; 165(10): 667-672, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37822249

RESUMO

INTRODUCTION: The case report describes the use of ultrasound-activated resorbable implants for surgical repair of comminuted cranial fractures in a 10 years old medium sized mix-breed dog being injured from a horse kick.


INTRODUCTION: Ce rapport de cas décrit l'utilisation d'implants résorbables activés par ultrasons pour la réparation chirurgicale de fractures crâniennes comminutives chez un chien de race moyenne âgé de 10 ans, blessé par un coup de pied de cheval.


Assuntos
Doenças do Cão , Fraturas Ósseas , Doenças dos Cavalos , Cães , Animais , Cavalos/cirurgia , Polímeros , Parafusos Ósseos , Fixação Interna de Fraturas/veterinária , Implantes Absorvíveis , Fraturas Ósseas/veterinária , Placas Ósseas/veterinária , Doenças do Cão/cirurgia
10.
Vet Surg ; 52(8): 1121-1127, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37655506

RESUMO

OBJECTIVE: To evaluate the use of bidirectional knotless barbed suture material for closure of the equine linea alba. STUDY DESIGN: Laboratory study. ANIMAL OR SAMPLE POPULATION: Adult light horse cadavers (n = 24). METHODS: A 25 cm incision was made through the linea alba, and a 200 L polyurethane bladder was positioned within the abdomen. The linea alba was closed either using USP2/EP5 bidirectional polydioxanone barbed suture or USP2/EP5 standard polydioxanone suture in a simple continuous pattern. Closure time was recorded for each suture type. The bladder was air-insufflated at 40 L/min, and the pressure at body wall failure recorded. The length of suture used for wound closure and wound failure modes were recorded. Suture length, closure time, bursting pressure, and failure modes were compared using Welch-Aspin t-tests. RESULTS: The incisional bursting pressure was comparable between the two groups (p > .05). Less suture material (p < .01) was required with the barbed suture than the standard suture. Closure time was less for the barbed suture than the standard suture (p < .01). Suture failure was the main failure mode in both groups (83% cases). CONCLUSIONS: Closure of the equine linea alba using bidirectional barbed suture material reduced the amount of foreign material in the wound and decreased closure time without compromising incisional strength. CLINICAL RELEVANCE: Bidirectional barbed suture material could be considered as an alternative to standard suture materials for closure of the equine line alba.


Assuntos
Parede Abdominal , Doenças dos Cavalos , Ferida Cirúrgica , Cavalos/cirurgia , Animais , Polidioxanona , Técnicas de Sutura/veterinária , Ferida Cirúrgica/veterinária , Suturas/veterinária
11.
Vet Surg ; 52(7): 994-1008, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37496312

RESUMO

OBJECTIVE: To develop a minimally invasive technique for placing a toggle construct across the coxofemoral joint of small equids using computer-assisted surgery. STUDY DESIGN: Experimental cadaveric study. SAMPLE POPULATION: Three pilot specimens: One donkey, one Shetland pony and one Warmblood foal. Six main study specimens: Three Shetland ponies, one American Miniature Horse, one Warmblood foal and one donkey. METHODS: Experimental surgeries were performed on both coxofemoral joints of each cadaver. Using a minimally invasive surgical approach, 5.5 mm bone canals were drilled through the femur and acetabulum, traversing the coxofemoral joint. Intraoperative guidance was provided by a cone-beam computed tomography (CBCT)-coupled surgical navigation system. A toggle construct was introduced through the bone canals. Surgical accuracy aberrations (SAA) were measured at the femoral entry and exit points and at the acetabular entry point on merged pre- and postoperative CBCT scans. The coxofemoral joint was assessed for articular cartilage damage by gross dissection. RESULTS: A toggle construct was placed across all 18 coxofemoral joints. The overall median SAA in the main study was 2.8 mm (range: 0.4-8.0 mm). No cartilage damage was found in the cadaveric specimens of the main study. CONCLUSION: The described technique allowed for the placement of a toggle construct across the coxofemoral joint of small equid cadaveric specimens without prior coxofemoral luxation. CLINICAL RELEVANCE: This technique may serve as an option for surgical stabilization of coxofemoral joints in small equids. Further biomechanical investigations are required to assess optimal implant positioning and toggle constructs.


Assuntos
Doenças dos Cavalos , Cirurgia Assistida por Computador , Animais , Cavalos/cirurgia , Estudo de Prova de Conceito , Articulação do Quadril/cirurgia , Cirurgia Assistida por Computador/veterinária , Equidae , Cadáver
12.
Vet Surg ; 52(7): 1015-1023, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37280741

RESUMO

OBJECTIVE: To assess oral buccal microcirculation by hand-held videomicroscopy in horses during colic surgery, comparing microcirculation values with macrocirculatory parameters and with those of healthy elective surgical horses. STUDY DESIGN: Clinical prospective study. ANIMALS: Client-owned horses (nine in the colic group; 11 in the elective group). METHODS: In the colic group, buccal mucosal side stream dark-field microscopy (DFM) videos, cardiac output (CO), mean arterial pressure (MAP), and lactate were obtained at three timepoints under general anesthesia (30, 90, and 150 min after induction). Video analysis was used to determine total vessel density, proportion of perfused vessels, perfused vessel density, and heterogeneity index. Dark-field microscopy videos, MAP, and lactate were obtained at a single timepoint under general anesthesia (45 min after induction) in the elective group. RESULTS: There were no differences in microcirculatory parameters between colic and elective horses, nor was there a difference across timepoints in the colic group. There was a weak negative correlation between microvascular parameters and CO (rho = -0.23). CONCLUSION: The colic group did not have decreased microcirculation in comparison with the healthy elective group. Dark-field microscopy did not correlate well with macrocirculatory parameters in the colic group. IMPACT: Dark-field microscopy may not be a sensitive enough indicator to detect differences in microcirculation between colic and elective groups. The lack of difference in microcirculation may be due to sample size, probe location, or variation in disease severity.


Assuntos
Cólica , Doenças dos Cavalos , Animais , Cólica/cirurgia , Cólica/veterinária , Procedimentos Cirúrgicos Eletivos/veterinária , Doenças dos Cavalos/cirurgia , Cavalos/cirurgia , Ácido Láctico , Microcirculação , Estudos Prospectivos
13.
Vet Surg ; 52(8): 1128-1139, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37302003

RESUMO

OBJECTIVES: To compare (1) performance of compact versus standard flute drill bits, (2) screw insertion properties and (3) pullout variables between interlocking thread (ITS) and buttress thread (BTS) self-tapping screws in third metacarpi. STUDY DESIGN: In vitro experimental study. SAMPLE POPULATION: Paired third metacarpi from 11 Thoroughbreds aged 2-4 years. METHODS: Screws were inserted into the lateral condylar fossae following bone preparation using the respective drill bit for each screw type. Screw pullout was achieved using a mechanical testing system. Density and porosity of bone surrounding screw holes was measured with microcomputed tomography following each pullout test. Drilling, screw insertion and pullout variables were compared between drill bit and screw types using repeated measures ANOVA. Linear regression analyses were used to characterize relationships between bone tissue properties and drill bit and screw outcomes. RESULTS: Maximum torque power spectral density (PSD) was lower for compact flute drill bits. Insertion torque was 50% higher for ITS. BTS had 33% greater preyield stiffness and 7% greater mean yield force. Bone tissue properties affected measured variables similarly for both screw and drill bit types. CONCLUSIONS: Lower torque PSD may increase durability of the compact flute drill bit. ITS had greater insertional torque, which may reflect greater bone engagement. BTS had greater resistance to axial pullout forces. CLINICAL SIGNIFICANCE: Metacarpal bone provides a simple model for comparison of drill bit and screw designs. Use of ITS to repair equine fractures subject to predominantly tensile forces is not justified based on the results of this study.


Assuntos
Doenças dos Cavalos , Ossos Metacarpais , Animais , Cavalos/cirurgia , Ossos Metacarpais/cirurgia , Microtomografia por Raio-X , Fenômenos Biomecânicos , Parafusos Ósseos/veterinária , Osso Cortical , Torque , Cadáver
14.
Vet Anaesth Analg ; 50(4): 363-371, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37055259

RESUMO

OBJECTIVE: To evaluate the impact of a 30% end-inspiratory pause (EIP) on alveolar tidal volume (VTalv), airway (VDaw) and physiological (VDphys) dead spaces in mechanically ventilated horses using volumetric capnography, and to evaluate the effect of EIP on carbon dioxide (CO2) elimination per breath (Vco2br-1), PaCO2, and the ratio of PaO2-to-fractional inspired oxygen (PaO2:FiO2). STUDY DESIGN: Prospective research study. ANIMALS: A group of eight healthy research horses undergoing laparotomy. METHODS: Anesthetized horses were mechanically ventilated as follows: 6 breaths minute-1, tidal volume (VT) 13 mL kg-1, inspiratory-to-expiratory time ratio 1:2, positive end-expiratory pressure 5 cmH2O and EIP 0%. Vco2br-1 and expired tidal volume (VTE) of 10 consecutive breaths were recorded 30 minutes after induction, after adding 30% EIP and upon EIP removal to construct volumetric capnograms. A stabilization period of 15 minutes was allowed between phases. Data were analyzed using a mixed-effect linear model. Significance was set at p < 0.05. RESULTS: The EIP decreased VDaw from 6.6 (6.1-6.7) to 5.5 (5.3-6.1) mL kg-1 (p < 0.001) and increased VTalv from 7.7 ± 0.7 to 8.6 ± 0.6 mL kg-1 (p = 0.002) without changing the VTE. The VDphys to VTE ratio decreased from 51.0% to 45.5% (p < 0.001) with EIP. The EIP also increased PaO2:FiO2 from 393.3 ± 160.7 to 450.5 ± 182.5 mmHg (52.5 ± 21.4 to 60.0 ± 24.3 kPa; p < 0.001) and Vco2br-1 from 0.49 (0.45-0.50) to 0.59 (0.45-0.61) mL kg-1 (p = 0.008) without reducing PaCO2. CONCLUSIONS AND CLINICAL RELEVANCE: The EIP improved oxygenation and reduced VDaw and VDphys, without reductions in PaCO2. Future studies should evaluate the impact of different EIP in healthy and pathological equine populations under anesthesia.


Assuntos
Pulmão , Respiração com Pressão Positiva , Cavalos/cirurgia , Animais , Estudos Prospectivos , Respiração com Pressão Positiva/veterinária , Volume de Ventilação Pulmonar/fisiologia , Dióxido de Carbono , Respiração Artificial/veterinária
15.
Vet Surg ; 52(4): 545-553, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36922367

RESUMO

OBJECTIVE: To describe a technique for a side-to-side jejunocecal anastomosis in horses using radiofrequency thermofusion (TF) of the intestines supported by a Cushing oversew and to compare this anastomosis to handsewn and stapled techniques. STUDY DESIGN: Ex vivo study. SAMPLE POPULATION: Intestinal tracts from 24 slaughtered horses. METHODS: A radiofrequency device was used to perform a jejunocecal anastomosis (Group RFA). The construction time and bursting pressure of this construct were compared with those of a hand-sewn double layer (Group HS) and stapled anastomoses (Group ST) without oversew of the staple line. Histology was also performed for the TF anastomoses to evaluate the extent of the thermal damage. RESULTS: The median (range) construction time (min) for the TF (15.8 [14.4-16.8]) was not significantly different from that for the HS (25.5 [24.2-26.3]) and ST (10.8 [9.7-12.5]) groups (p = .07). The construction time for ST was shorter than that for HS group (p < .001). The average (standard deviation) bursting pressure (mmHg) for HS (153.1 +/- 17.5) was higher than that for RFA (76 +/- 15) and ST groups (48 +/- 13; p < .001). The bursting pressure of the RFA was higher than that of the ST anastomoses (p = .001). The thermal damage caused by the device was within the suture oversew in the deeper layers, whereas it extended a few mm beyond the suture line in the serosa. CONCLUSION: Radiofrequency assisted anastomoses provide similar construction times to current techniques and have a higher bursting pressure than ST anastomoses. CLINICAL SIGNIFICANCE: Radiofrequency-assisted anastomoses with a suture oversew demonstrated comparable bursting pressures to ST anastomoses. The use of the radiofrequency device on the intestine is extra label and causes serosal tissue damage, which may increase the risk of adhesions.


Assuntos
Intestino Delgado , Técnicas de Sutura , Animais , Cavalos/cirurgia , Anastomose Cirúrgica/veterinária , Anastomose Cirúrgica/métodos , Técnicas de Sutura/veterinária , Grampeamento Cirúrgico/veterinária , Intestinos
16.
Am J Vet Res ; 84(5)2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-36867543

RESUMO

OBJECTIVES: Evaluation of the strength of the novel suture technique by comparison with a 2-interrupted suture technique. SAMPLE: 40 equine larynges. PROCEDURES: 40 larynges were used; 16 laryngoplasties were performed using the currently accepted 2-suture technique and 16 using the novel suture technique. These specimens were subjected to a single cycle to failure. Eight specimens were used to compare the rima glottidis area achieved with 2 different techniques. RESULTS: The mean force to failure, as well as the rima glottidis area of both constructs, were not significantly different. The cricoid width did not have a significant effect on the force to failure. CLINICAL RELEVANCE: Our results suggest that both constructs are equally strong and can achieve a similar cross-sectional area of the rima glottidis. Laryngoplasty ("tie-back") is currently the treatment of choice for horses with exercise intolerance due to recurrent laryngeal neuropathy. Failure to maintain the expected degree of arytenoid abduction post-surgery occurs in some horses. We believe this novel 2-loop pulley load-sharing suture technique can help achieve and, more importantly, maintain the desired degree of abduction during surgery.


Assuntos
Laringoplastia , Laringe , Cavalos/cirurgia , Animais , Laringoplastia/veterinária , Laringoplastia/métodos , Laringe/cirurgia , Cartilagem Aritenoide/cirurgia , Técnicas de Sutura/veterinária , Suturas/veterinária
17.
Vet Comp Orthop Traumatol ; 36(4): 184-192, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36758617

RESUMO

OBJECTIVE: The aim of this study was to compare the biomechanical properties of two minimally invasive arthrodesis techniques of the equine proximal interphalangeal (PIP) joint (three transarticular 5.5-mm cortical screws [AO-3TLS] vs. two transarticular 7.0-mm headless cannulated multi-use compression screws [MUC-2TS]) in dynamic non-destructive testing and compression testing to failure. STUDY DESIGN: The experimental study included six pairs of cadaveric adult equine forelimbs; one limb from each horse was randomly assigned to one of the treatments, and the contralateral limb was submitted to the remaining treatment. The dynamic test was performed alternating non-destructive compression tests at a displacement rate of 5 mm/min up to 5,000 N and sinusoidal compressive cyclic tests at 6 Hz, using a 3,600-N amplitude for 8,550 cycles. Construct stiffness and maximum sagittal plane rotation about the PIP joint markers were determined during the dynamic test. After the dynamic test reached 136,800 cycles, the monotonic compressive test until failure was performed on each construct: load, displacement and sagittal plane rotation about the PIP joint marker at failure were analysed. RESULTS: The evaluated biomechanical properties showed no statistical difference between the AO-3TLS and MUC-2TS treatment groups in any of the ramps of the dynamic non-destructive test and in the compression loading until failure test. CONCLUSION: The MUC-2TS treatment produced biomechanical properties equivalent to the AO-3TLS treatment for PIP joint arthrodesis.


Assuntos
Parafusos Ósseos , Articulação do Dedo do Pé , Cavalos/cirurgia , Animais , Articulação do Dedo do Pé/cirurgia , Parafusos Ósseos/veterinária , Fenômenos Biomecânicos , Articulações , Artrodese/veterinária , Artrodese/métodos
18.
Vet Surg ; 52(3): 428-434, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36691965

RESUMO

OBJECTIVE: This study investigated the elongation following cyclic loading on square knots of 5 USP multifilament long-chain ultra-high molecular weight polyethylene core (UHMWPE), 2 mm woven UHMWPE tape, and 5 USP braided polyester, with and without cyanoacrylate glue. STUDY DESIGN: Experimental study. SAMPLE POPULATION: n = 4. METHODS: Three conditions (suture without knot, suture with knot, suture with knot + cyanoacrylate) were evaluated for each suture material on a mechanical test stand by measuring the increased length of the construct after cycling from 25 to 50N for 1000 repetitions at 20 mm/second. Knot elongation was determined by subtracting the length of the control suture from the suture with knot or suture with knot + cyanoacrylate. The data were analyzed with a linear regression model with robust estimation of variance. Post-hoc analysis determined the model adjusted differences (square knot vs. cyanoacrylate) as a difference from control. t-tests were conducted to identify the significant findings. RESULTS: Total elongation of polyester (6.2-7.8 mm) was greater than multifilament UHMWPE (3.4-6.4 mm) and UHMWPE tape (2-3.7 mm) for all conditions. Polyester had the lowest knot elongation (1.6 mm) and the addition of cyanoacrylate decreased knot elongation for polyester by 1 mm. CONCLUSIONS: Polyester had the most total construct elongation followed by multifilament UHMWPE and UHMWPE tape. Polyester showed the least knot elongation and cyanoacrylate decreased this knot elongation. CLINICAL SIGNIFICANCE: Total construct and knot elongation should be considered as contributing factors to loss of arytenoid abduction following prosthetic laryngoplasty when using polyester, multifilament UHMWPE, or UHMWPE tape. Addition of cyanoacrylate to polyester knots should be explored to limit elongation.


Assuntos
Cianoacrilatos , Laringoplastia , Cavalos/cirurgia , Animais , Cianoacrilatos/uso terapêutico , Laringoplastia/veterinária , Técnicas de Sutura/veterinária , Resistência à Tração , Poliésteres , Suturas/veterinária , Teste de Materiais/veterinária
19.
Vet Surg ; 52(3): 388-394, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36625237

RESUMO

OBJECTIVE: To develop and describe a minimally invasive, ultrasound-guided, percutaneous technique for the desmotomy of equine palmar/plantar annular ligaments (PALs) using a transecting thread. STUDY DESIGN: Ex vivo study. SAMPLE POPULATION: Twenty-one normal equine distal limb specimens. METHODS: Under ultrasonographic guidance, a surgical thread was percutaneously placed around the PAL through 2 skin punctures (proximal and distal) using a 18 gauge spinal needle in equine limbs (11 forelimbs, 10 hindlimbs) with normal PALs. The ligament was transected by a back-and-forth motion of the thread until the loop emerged from the proximal skin puncture site. Each specimen was dissected and assessed for completeness of transection and iatrogenic damage under direct visualization. Descriptive statistics were reported. RESULTS: The PAL was completely transected in 17/21 limbs. The mean duration of the procedure was 16 minutes. Superficial needle puncture or subtle abrasion of the superficial digital flexor tendon was noticed in 4 limbs. No iatrogenic injury to other intrathecal structures was identified. After PAL division, the needle entry and exit points had a mean diameter of 1.2 and 1 mm, respectively. CONCLUSION: Desmotomy of normal PALs in equine limb specimens was performed effectively using the percutaneous thread-transecting technique with minimal iatrogenic damage to adjacent structures. CLINICAL SIGNIFICANCE: Information from this study will allow refinement of the technique for use in equine clinical cases either in standing or anesthetized horses.


Assuntos
Doenças dos Cavalos , Cavalos/cirurgia , Animais , Doenças dos Cavalos/cirurgia , Ligamentos/cirurgia , Tendões/cirurgia , Extremidades , Membro Anterior/cirurgia
20.
Vet Surg ; 52(3): 407-415, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36084150

RESUMO

OBJECTIVE: To compare single-layer anastomoses (modified continuous Lembert [mod-CL] and modified-interrupted Lembert [mod-IL]) and a 2-layer simple continuous anastomosis (2 L; seromuscular and mucosal) for jejunojejunal anastomoses in equine cadavers and to compare ex vivo to in vivo time to complete the anastomosis and stoma size with a mod-IL pattern. STUDY DESIGN: Measurements in jejunum from cadaver and anesthetized horses. ANIMALS: Ten live horses and 18 equine cadavers. METHODS: Time to complete anastomosis, bursting pressures (BP), leakage sites, and anastomotic index (size ratio of anastomotic lumen to control lumen) were recorded. Time to completion and lumen size were compared between in vivo and ex vivo mod-IL patterns. RESULTS: The mod-CL pattern was fastest (8.44 ± 1.30 min, p < .05), and the 2 L pattern was slower (17.07 ± 2.0 min) than the mod-CL and mod-IL (p < .05). The anastomotic index exceeded 100 and did not differ between patterns. Segments reached higher bursting pressures when anastomosed with mod-IL (145.94 ± 24.18 mm Hg) than mod-CL (p < .05). In vivo closure was approximately 8 minutes slower than ex vivo, and with a smaller anastomotic index. CONCLUSIONS: All anastomoses increased lumen size over control segments ex vivo. Lumen size after placement of a mod-IL was greater ex vivo than in vivo, and completion was slower in vivo than ex vivo. [Corrections added on 26 Dec 2022, after online publication: added "ex vivo" to the first line of Conclusions in the Abstract.] CLINICAL SIGNIFICANCE: Slower and smaller anastomoses should be anticipated in vivo compared to ex vivo results. Anastomoses with a mod-IL pattern appear clinically advantageous, producing a comparable lumen size in less time than 2 L.


Assuntos
Doenças dos Cavalos , Técnicas de Sutura , Cavalos/cirurgia , Animais , Técnicas de Sutura/veterinária , Intestino Delgado/cirurgia , Jejuno/cirurgia , Anastomose Cirúrgica/veterinária , Anastomose Cirúrgica/métodos , Cadáver , Doenças dos Cavalos/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...